summaryrefslogtreecommitdiff
path: root/autoplace.lua
AgeCommit message (Collapse)Author
2013-06-26Added support to autoroute code for technic deployer and nodebreakerVanessa Ezekowitz
2013-06-24actually, filters should only connect from the right/output side since theyVanessa Ezekowitz
can't actually receive anything from the input side via a tube.
2013-06-23rewrote autoplacement code to make it more aware of filters,Vanessa Ezekowitz
autocrafter, nodebreaker, deployer, and made sure each item will only initiate a connection to those sides which can accept such. Fixed various autorouting bugs as I ran across them. Autorouting for various devices is now: filters: left and right sides only nodebreaker, deployer: back only autocrafter: all six sides chests: top, bottom, left, right, back (not front) furnace: bottom, left, right, back (not the top or front)
2013-06-08Add vertical version of airtight pipe entryVanessa Ezekowitz
if automatically rotates to connect to the thing you point at, if a connection is possible.
2013-05-10add flow sensor. Sends mesecons signal when water is flowing through it.Vanessa Ezekowitz
2013-01-20Added chests and furnaces autoconnect to tubes.Novatux
Fixed a bug where autocrafter could bbe used to clone items. Removed test code.
2013-01-19Added autocrafter.Novatux
Fixed a bug where items in mese tubes disappeared whan placing or removing a tube next to it.
2013-01-16Added a function to register tubes.Novatux
Added the mese pipe.
2013-01-05made storage tanks connect from top/bottom, made storage tank and pipeVanessa Ezekowitz
textures use the ^ combine operator so they can show the actual liquid going through the pipes/tanks.
2013-01-04minor spacing tweaks, nothing functionalVanessa Ezekowitz
2013-01-04First stage of integrating Mauvebic's water flowing code. This is experimentalVanessa Ezekowitz
and doesn't move water yet - but at least it doesn't break anything :-)
2013-01-01fixed facedir/rotation bug in placement of expansion tanks.Vanessa Ezekowitz
2013-01-01changed default orientation of spigot to make it easier to place.Vanessa Ezekowitz
2013-01-01added a "sealed" entry/exit panel (really just a horizontal pipe with a metalVanessa Ezekowitz
panel overlayed into the middle). Also, tweaked pipes to always drop the empty ones.
2013-01-01revamped pumps so that now they should sit in/on liquid and be connected onlyVanessa Ezekowitz
from the top, relegated grates to decorational-only, added outlet spigot. Got rid of a few obsolete textures. Got rid of that whole _x and _z naming thing, now all directional devices (pumps, valves, spigots, tanks) use facedir. Valves, spigots no longer auto-rotate to find nearby pipes.
2012-09-17Added test object for pneumatic tube autorouting code, made tubes connect toVanessa Ezekowitz
it and any object that bears groups={tubedevice=1} (connects to any side)
2012-08-24Added pneumatic tubes with their own autoplace code (does not connect toVanessa Ezekowitz
steel pipes). Fixed a recursion bug that sometimes caused a stack overflow.
2012-08-22Added "expansion tank" that appears if the user stacks tanks upwards.Vanessa Ezekowitz
(Downwards is not checked).
2012-08-22Extended storage tank to show fill level in 10% steps (0% to 100%).Vanessa Ezekowitz
2012-08-22Added outlet grate, made it participate in autoplace algorithm.Vanessa Ezekowitz
2012-08-21made storage tanks' upper/lower fittings and intake grate fitting participateVanessa Ezekowitz
in pipe autoplace algorithm
2012-08-21minor opps/bugfix - devices should not look above/below them normally :-)Vanessa Ezekowitz
2012-08-21reorganized code a bit to allow for upcoming rules changes.Vanessa Ezekowitz
2012-08-21Made storage tank participate in autoplace algorithm. Tuned API aVanessa Ezekowitz
little to allow for more flexible placement.
2012-08-19Pumps and valves now fully participate in the auto-rotate/auto-route process.Vanessa Ezekowitz
These devices can only be connected to horizontal pipes or to each other. Note that only the device being placed and the pipes around it will adapt; if you have a valve and pump next to one another and they won't connect, put a piece of pipe at one end to show the auto-rotator which way they should go. Removal of a pipe or device will not change the orientation of surrounding devices.